Ice
Equipment International
![]()
HYDRAULIC "CB"
SERIES ICE RAKE
Model Capacity ~1
(U.S. Tons of Ice) Approx. Shipping
weight, pounds Floor Space Required ~2
(L x W x H)
CB-20 20 2,000 24'-9"x11'-6"x 9'-0"
CB-35 30 2,100 24'-9"x11'-6"x11'-10"
CB-38 38 2,200 24'-9"x11'-6"x13'-6"
CB-50 50 2,300 24'-9"x12'-0"x16'-4"
CB-31 31 3,000 29'-9"x14'-0"x 9'-0"
CB-49 49 3,150 29'-9"x14'-0"x11'-10"
CB-59 59 3,250 29'-9"x14'-0"x13'-6"
CB-75 75 3,350 29'-9"x14'-6"x16'-4"
CB-87 87 3,500 29'-9"x16'-6"x16'-4"

~1 Capacity based upon ice density of 40 pounds per cubic foot(640kg/cu. meter)
for TURBO fragmented ice(CF & CAR models). For other ice products derate
capacity as follows:
TURBO TIG/TIGAR fragmented ice 0.90(Correction Factor)
VOGT tube ice(all diameters) 0.85(Correction Factor)
~2 Includes space required for mounting the hydraulic cylinder and power unit,
vertical bin braces, control panel, and rake bin door hand winch, and a 24
inch clearance at the front to operate the door handwinch. Additional space,is
required for service access to the hydraulic unit, most electrical codes also
require a 36inch clearance in front of the electrical panel. Does not include
space required for floor screw drive. Dimensions subject to change without
notice. Reference data sheet for installation dimensions.
Included is the rake assembly, stainless steel girder liners, rake bin structure
with aluminum bin liner, rake drive motor, hydraulic power unit and hoist
assembly, hand winch for door, rake bin door, retaining wall for bin door
assembly, installation drawings, Operating and Maintenance manuals, floor
screw limit switch assembly, and controls for loading and unloading ice. Floor
screw conveyor for ice delivery is not included. Electrical control panel
includes controls and motor starters for all motors supplied. Motor starter
for floor screw is included. Load detector and electro-mechanical controls
are standard. Motor starter for floor screw is included. Rake assembly is
factory assembled for testing. Rake components are "match marked"
and disassembled prior to shipment.
AUTOMATIC ICE RAKES
Model Capacity ~1
(U.S. Tons of Ice) Approx. Shipping
weight, pounds Floor Space Required ~2(L x W x H)
15' * 30' 9.0 7,500 38'-2"x17'-11"x'H'
15' * 35' 10.5 8,250 43'-2"x17'-11"x'H'
20' * 35' 14.0 9,000 43'-2"x22'-11"x'H'
20' * 40' 16.0 9,750 48'-2"x22'-11"x'H'
20' * 45' 18.0 10,150 52'-9"x22'-11"x'H'
20' * 50' 20.0 10,900 58'-2"x22'-11"x'H'
20' * 55' 22.0 11,300 63'-2"x22'-11"x'H'
~1 Capacity based upon ice density of 40 pounds per cubic foot(640kg/cu. meter)
for TURBO fragmented ice(CF & CAR models). For other ice products derate
capacity as follows:
TURBO TIG/TIGAR fragmented ice 0.90(Correction Factor)
VOGT tube ice(all diameters) 0.85(Correction Factor)
~2 Includes space required for mounting control panel, and rake bin door hand
winch, 24 inch clearance at the front to operate the door hand winch, and
base plate flanges on the vertical rake steel columns. In addition to the
space listed above most electrical codes also require a 36 inch clearance
in front of the electrical panel. Does not include space required for floor
screw drive. Dimensions subject to change without notice. Reference data sheet
for installation dimensions.
Included is the rake assembly, stainless steel girder liners, rake drive motor,
hoist assembly, hand winch for door, rake bin door, limit tube assembly, installation
drawings, Operating and Maintenance manuals, floor screw limit switch assembly,
and controls for loading and unloading ice. Floor screw conveyor for ice delivery
is not included. Bin structure and bin liner are not included. Electrical
control panel includes controls and motor starters for all motors supplied.
Includes motor starter for floor screw provided by others. Load detector and
programmable controller controls are standard. Rake assembly is factory assembled
for testing. Rake components are "match marked" and disassembled
prior to shipment.
~3 Overall height 'H' is determined by adding 5'-3" to the ice height.
Ice heights are available in one foot increments from 8 feet to 18 feet. Desired
ice capacity (U.S. tons) divided by tons/ft. (above) equals ice height rounded
to the nearest foot. Ideal ice height is 12 feet. Example: For a 20' * 45'
rake with 210 U.S. desired tons storage capacity
Ice height = 210 U.S tons / 18.0 tons/ft = 11.67ft.
Specify 12 feet ice height. Actual storage capacity=216.0 U.S.tons
RAKE OPTIONS
Power bin door operator(hydraulic)
Rake drive soft start (Required with plastic chain)
Programmable controller(CB rakes only. Standard on Automatic Ice Rake.
Stainless Steel components
1. Drive & Idler Shafts
2. Rake flite chain
3. Rake flite sprockets
4. Flites
5. Bin Liner
6. Bin door liner
7. Rake hoist cables
Plastic Components(CB rake only. Requires soft start option)
1. Rake flite chain
2. Rake flite sprockets
Nylon girder liner
Rake flite failure limit switch
Rake bin empty & full limit switches(CB rake only)
Ice delivery control systems
Galvanized bin structure with aluminum liner(Automatic Rake only)
Call for Information
1-800-463-4333 or 613-386-7381
or
Click Here to Request More Information